Koiri Make 1 KVA 1:1 Phase On-Line UPS


Model Number: DM01E0311

UPS System On Line UPS

Price: 14750
MRP: 29972 You Save: 15222

KOIRI High Frequency Online UPS systems are advanced double-conversion solutions designed to provide uninterrupted, pure sine wave power for critical equipment. These UPS units offer high efficiency and ultra-fast transfer time (<1ms), making them ideal for data centers, industrial control systems, and sensitive electronic devices.

  • Features
  • Online/Double Conversion

    Automatic Voltage Regulation (AVR)

    Surge Protection

    Generator Compatibility

    Inbuilt Isolation Transformer

    Pure Sine Wave Output

    LCD/LED Display

    Audible Alarms

    Overload Protection

    Hot-Standby Feature (1+1)

  • Applications
  • Data Centers

    Hospitals and Medical Equipments.

    Commercial Buildings

    Oil and Gas Industry

    Telecommunications

    Educational Institutions

    Government Facilities

    Server Rooms

    Security Systems

    Specification

    General Specifications
    Isolation Transformer
    Optional
    Output Specification
    Output Capacity (KVA )
    1 KVA
    Output Capacity (KW )
    .9 KW
    Output Power Factor
    0.9 Power Factor
    Output Phase
    1 Or Phase
    Other Output Phase
    1 Or Phase
    Output Voltage
    230 Volt
    Other Output Voltage
    208 Or 240 Volt
    Efficiency at Full Load
    > 94 %
    Output Voltage Distortion
    < =3 %
    Output Frequency (sync to mains)
    50/60Hz +/- 3 Hz
    Output Frequency (not synced)
    +/- 0.1% for 50/60Hz Nominal
    Load Crest Factor
    3:1
    Output Voltage THD
    < =3 %
    Transfer Time
    < 0 ms
    Output Waveform type
    Sine Wave
    Output Connections
    IEC Socket & Hard Wire
    Bypass
    Internal Bypass (automatic & manual)
    Overload Capacity
    Optional
    Input Specification
    Input Voltage
    220 240 Volt
    Other Input Voltage
    120 Or 300 Volt
    Input Phase
    1 Phase
    Other Input Phase
    1 Or Phase
    Input frequency
    50/60Hz +/- 3 Hz
    Input frequency Range
    45 - 55 Hz
    Input Power Factor
    > 0.99
    Input Connections
    Hard Wire 3 wire (1PH+N+G), Hard Wire 5-wire (3PH + N + G)
    Input Protection
    Thermal Circuit Breaker
    Batteries & Runtime
    Battery DC Bus
    36 - VDC
    Maximum Charger Capacity
    6 Amp.
    Battery Position Option
    External
    Battery Type Compatibility
    SMF / Flooded Batteries
    Batteries Recharge Time upto 90%
    < 8 9 Hrs.
    Approved Battery Capacity (AH)
    17 - 65 Amp.
    Communication & Management
    Control panel
    Graphical LCD Display
    SNMP Management
    Optional
    Power Management Software
    Optional
    Interface Port(s)
    DB-9 RS-232, Smart-Slot
    Audible Alarm
    Audible and visible alarms prioritized by severity
    Physical
    Maximum Height
    0 Mm
    Maximum Width
    0 Mm
    Maximum Depth
    0 Mm
    Net Weight
    0 Kg
    Environmental
    Operating Relative Humidity
    0 - 95 % Rh
    Operating Elevation
    0 - 1000 Meters
    Storage Temperature
    0 - 55 °C

    Documentation

    Item Catalogue
    Koiri_make_online UPS
    pdf

    Options